In the catering industry and meat processing factories in Hong Kong, the HOBART bone cutter, as a high-performance industrial equipment, undertakes the task of processing hundreds of kilograms of food every day. However, when the equipment suddenly fails such as "no response when powered on" or "stopping at startup", it will directly affect the operation of the production chain. This article is written by a team of senior engineers from Junhong Electric, which deeply analyzes the causes of electrical system failures of the HOBART bone cutter, and provides immediate solutions and preventive maintenance guidelines.


---


## 1. 5 major electrical system causes of HOBART bone cutter startup failure


### 1. **Abnormal main power input (accounting for 38% of the failure rate)**

- **Typical symptoms**

No display on the control panel/all indicator lights are off, and the equipment is completely unresponsive

- **Detection points**

- Hong Kong voltage stability test (standard 220V±10%)

- Power socket ground wire impedance test (needs ≤0.1Ω)

- Industrial plug internal copper sheet oxidation degree inspection

- **Junhong special solution**

Use FLUKE 1587 insulation resistance tester for three-stage testing:

▶️ Input voltage fluctuation analysis (capture instantaneous voltage drop)

▶️ Cable insulation layer aging scan (focus on detecting bends)

▶️ Phase balance calibration (applicable to three-phase 380V models)

### 2. **Motor protection system triggering (accounting for 27% of the failure rate)**

- **Fault manifestation**

After power-on, the motor makes a buzzing sound but cannot start, or trips after running for 2-3 seconds

- **Core inducement**

- Winding inter-turn short circuit (mostly occurs in humid environments)

- Bearing jamming causes starting current overload (common values ​​> rated current 300%)

- Thermal relay calibration offset (error >±15%)

- **Technical processing flow**

1. Megohmmeter to detect motor insulation resistance (standard value ≥ 2MΩ)

2. Infrared thermal imaging device to scan terminal temperature rise

3. Dynamic torque test to determine mechanical load abnormality


### 3. Control module failure (failure rate 19%)

- **Multiple models**

HOBART 6612/8816 series (using Siemens S7-1200 PLC control system)

- **Diagnostic indicators**

- I/O module communication error code (such as E21/E45 alarm)

- Relay contact arc erosion degree

- 24V DC power output stability (fluctuation needs to be ≤±5%)

- **Junhong original factory repair**

- Provide HOBART authorized control board burning service

- Use imported silver-cadmium alloy to replace damaged relay contacts

### 4. **Safety interlock device abnormality (accounting for 11% of the failure rate)**

- **Key protection mechanism**

- Knife cover micro switch (open circuit impedance > 0.5Ω triggers protection)

- Overload clutch displacement sensor (detection accuracy 0.1mm)

- **On-site debugging points**

- Use laser alignment instrument to calibrate the sensor installation angle

- Simulate load test safety device response time (should be < 0.3 seconds)


### 5. **Inverter parameter inaccuracy (accounting for 85% of inverter faults)**

- **Typical fault codes**

- F0001 (overcurrent) / F0003 (undervoltage) / F0041 (motor parameter error)

- **In-depth adjustment service**

- V/F curve optimization (matching Hong Kong power grid characteristics)

- Carrier frequency resetting (eliminating high-frequency harmonic interference)


---


## 2. Junhong Electric's four major technical advantages guarantee maintenance quality


### 1. **Industrial-grade diagnostic equipment matrix**

- German KIMO multi-parameter power quality analyzer

- American Amprobe motor fault diagnosis system

- Japanese HIOKI storage oscilloscope (100MHz bandwidth)


### 2. **Original parts supply chain**

- Direct supply of HOBART certified accessories (with original anti-counterfeiting labels)

- Key parts spare parts list:

✅ Main contactor (model: LC1D09M7)

✅ Encoder (model: E6B2-CWZ6C)

✅ Drive gear set (hardness HRC58-62)


### 3. **Hong Kong localized service system**

- **Rapid response**: 90 minutes on-site at industrial areas such as Mong Kok/Kwun Tong/Tsuen Wan

- **Special time**: Provide emergency maintenance time for slaughterhouses in the early morning

- **Data traceability**: Establish equipment health files (including vibration spectrum records)


---


## 3. Emergency fault response guide (before maintenance personnel arrive)


| Fault phenomenon | Operable inspection | Absolutely prohibited behavior |

|---------|------------|-------------|

| No response after power on | 1. Verify the status of the workshop circuit breaker<br>2. Check whether the emergency stop button pops up | Short-circuiting the fuse is strictly prohibited |

| Abnormal tripping | 1. Record the working time before tripping<br>2. Photograph the control panel alarm code | Continuous forced start is prohibited |

| Smoke/odor | 1. Immediately cut off the main power supply<br>2. Move surrounding flammable materials | Do not splash water to cool down |


---


## 4. Deep maintenance plan to extend equipment life


### ▶️ Daily inspection items

- Clean the bone residue on the blade (to prevent the accumulation of conductive dust)

- Verify the function of the emergency stop device


### ▶️ Monthly maintenance focus

- Spindle bearing oiling (using Molykote EM-50L high temperature grease)

- Clean the heat dissipation duct (compressed air pressure must be ≤0.3MPa)


### ▶️ Annual maintenance service

- Power harmonic analysis and control

- Torque wrench calibration transmission system (accuracy ±3%)


---


## V. Repair Case Verification


**Case 1: Sudden shutdown of HOBART 8816 in a frozen food factory in Hong Kong**


- Fault phenomenon: The motor vibrates and trips immediately after startup


- Junhong Testing:


1. The motor insulation resistance is only 0.5MΩ (standard ≥2MΩ)


2. Moisture condensation is found in the winding


- Solution:


✅ Vacuum drying (65℃ for 8 hours)


✅ Coating with conformal coating (in compliance with IP54 standard)


- Repair effect: The equipment has been running continuously for 18 months without abnormality


---


**24-hour emergency support**

When your HOBART device has an abnormality, please call Junhong Electric Repair Center immediately at +852 5531 1921

▶️ Provide "No power on, no charge" testing commitment

▶️ Large food factories can sign annual maintenance agreements

 
 
 